zwe certificate pkcs12 lock
zwe certificate pkcs12 lock
zwe > certificate > pkcs12 > lock
zwe certificate pkcs12 lock [parameter [parameter]...]
#
DescriptionThis command will lock the keystore directory to only be accessible by specified user group.
#
Inherited from parent commandWARNING: This command is for experimental purposes and could be changed in the future releases.
#
Exampleszwe certificate pkcs12 lock -d /path/to/my/keystore/dir --user keystore-user --group keystore-group
#
ParametersFull name | Alias | Type | Required | Help message |
---|---|---|---|---|
--keystore-dir | -d | string | yes | |
--user | string | yes | ||
--group | string | yes | ||
--group-permission | string | no |
#
Inherited from parent commandFull name | Alias | Type | Required | Help message |
---|---|---|---|---|
--help | -h | boolean | no | |
--debug,--verbose | -v | boolean | no | |
--trace | -vv | boolean | no | |
--silent | -s | boolean | no | |
--log-dir,--log | -l | string | no | |
--config | -c | string | no |
#
ErrorsError code | Exit code | Error message |
---|---|---|
ZWEL0177E | 177 | Failed to lock keystore directory %s. |
#
Inherited from parent commandError code | Exit code | Error message |
---|---|---|
100 | If the user pass --help or -h parameter, the zwe command always exits with 100 code. | |
ZWEL0101E | 101 | ZWE_zowe_runtimeDirectory is not defined. |
ZWEL0102E | 102 | Invalid parameter %s. |
ZWEL0103E | 103 | Invalid type of parameter %s. |
ZWEL0104E | 104 | Invalid command %s. |
ZWEL0105E | 105 | The Zowe YAML config file is associated to Zowe runtime "%s", which is not same as where zwe command is located. |
ZWEL0106E | 106 | %s parameter is required. |
ZWEL0107E | 107 | No handler defined for command %s. |
ZWEL0108E | 108 | Zowe YAML config file is required. |
ZWEL0109E | 109 | The Zowe YAML config file specified does not exist. |
ZWEL0110E | 110 | Doesn't have write permission on %s directory. |
ZWEL0111E | 111 | Command aborts with error. |
ZWEL0112E | 112 | Zowe runtime environment must be prepared first with "zwe internal start prepare" command. |
ZWEL0120E | 120 | This command must run on a z/OS system. |
ZWEL0121E | 121 | Cannot find node. Please define NODE_HOME environment variable. |
ZWEL0122E | 122 | Cannot find java. Please define JAVA_HOME environment variable. |
ZWEL0123E | 123 | This function is only available in Zowe Containerization deployment. |
ZWEL0131E | 131 | Cannot find key %s defined in file %s. |
ZWEL0132E | 132 | No manifest file found in component %s. |
ZWEL0133E | 133 | Data set %s already exists. |
ZWEL0134E | 134 | Failed to find SMS status of data set %s. |
ZWEL0135E | 135 | Failed to find volume of data set %s. |
ZWEL0136E | 136 | Failed to APF authorize data set %s. |
ZWEL0137E | 137 | z/OSMF root certificate authority is not provided (or cannot be detected) with trusting z/OSMF option enabled. |
ZWEL0138E | 138 | Failed to update key %s of file %s. |
ZWEL0139E | 139 | Failed to create directory %s. |
ZWEL0140E | 140 | Failed to translate Zowe configuration (%s). |
ZWEL0142E | 142 | Failed to refresh APIML static registrations. |
ZWEL0172E | Component %s has %s defined but the file is missing. |